Bc Electrical Code Kitchen Receptacles
Outlets must be no more than 1 8m apart measured along the wall behind a counter top and no more than 900m from a sink stove or end point.
Bc electrical code kitchen receptacles. Or can it be on the underside of it or perhaps on the side of the island. A 20 amp receptacle is designed to accept the special plug on heavier use appliances and if such an appliance plugs into a 15 amp circuit there is a danger of drawing too much power and. It will work either way but if you going to put a receptale below the countertop by underside or side of island the thing ya have to keep in your mind is the distance of overhang of counter. When planning out kitchen receptacle placement it is important to remember that the rule talks about counter work surfaces not wall spaces.
Most of it however originates from people who work in the field. Once receptacles have been installed in the building and have met electrical code standards the construction company is free to use those receptacles for basic use regardless of whether or not they have gfci outlets. There is no danger to installing 15 amp outlet receptacles on a 20 amp circuit in fact this is the standard practice but under no circumstances should a 20 amp receptacle be installed on a 15 amp circuit. This is what is known as a split receptacle kitchen circuit.
It provides instructions about the location of panelboards placement of receptacles in closets balconies and counters altering existing branch circuits and the location of outlet branch circuit type arc fault interrupters. This directive provides clarification on the interpretation of section 26 of the bc electrical code. No more than 12 outlets should be on a branch circuit. Electrical code basics and recommended practices for kitchen renovation often seem like pointless rules cooked up in an office boardroom as electrical code eventually does get hammered out across conference tables.
However this requirement predates the requirement for counter receptacles and circuits. Trish what you have is actually a perfectly normal situation which meets the code rules in many electrical jurisdictions. For safety reasons gfci outlets are required if the receptacle is being used to give power to construction tools or equipment. Electricians contractors and other industry professionals.
It is fed by a 2 pole 15a circuit breaker and uses 14 2 cable. Kitchen wall not counter receptacles 2015 code separate branch circuit required 2018 code separate branch circuit not required wall receptacles provided in a kitchen are required to be supplied by a separate circuit. 26 602 panelboards in dwelling units subrule 1. Understanding the kitchen split receptacle circuit.
Does a receptacle on a kitchen island have to be mounted on the counter top.