Basement Wall Insulation R Value Code
Generally zones 1 and 2 cover the southern states which suggest no necessary values to r 10 for basement walls.
Basement wall insulation r value code. Cold humid climates require insulation with greater r values than warm dry climates. The table below shows what levels of insulation are cost effective for different climates and. I think i ve made a mistake and am worried i ve not put enough xps insulation up before building my studs. The department of energy provides a service to determine the exact r value required based on zip code and type of heating fuel.
The higher the r value the greater the insulation performance. Want to use rigid pink foam boards for concrete 1 5 r7 5 and batt insulation for wall r14. Trying to figure out building code for ontario what r value and what insulation along with vapor barrier is up to code. When determining how much insulation you need don t guesstimate calculate.
R value measures how well certain building insulation materials can resist heat. 2015 code requires walls to be insulated with a minimum of r 20 or r 13 5 13 5 means r 13 cavity insulation plus r 5 insulated sheathing. Recommended home insulation r values. Does anyone know for sure what the r value requirements are for a basement reno.
The ontario building code act gives both contractors and homeowners a baseline that ensures safe and comfortable interiors. How are insulation materials affected by the code. Improve the insulation in your attic on your above grade walls in the basement and in exposed floors for a more comfortable and energy efficient home. R value is a measure of insulation s ability to resist heat traveling through it.
The higher the r value the better the thermal performance of the insulation. Foam plastic insulation on the interior of the building envelope must adhere to the requirements of protection of foamed plastics as per 9 10 17 10 of the national building code of canada. In such cases where r value is assigned this may decrease the r value requirement for batt insulation. If structural sheathing covers 40 or less of the exterior continuous insulation r value shall be permitted to be reduced by no more than r 3 in the locations where structural sheathing is used to maintain a consistent total sheathing.
The basement walls need to be insulated to a minimum value of r 10 for continuous insulation such as foam plastic insulation or r 13 for framing cavity insulation based on the component requirements of table n1102 1 insulation and fenestration requirements by component. Know exactly how much you need with our project calculators.